Unishkova L.I., Pashtaev N.P., Pozdeeva N.A. ANALYSIS OF CHANGES IN THE ABERRATIONS OF THE OPTICAL SYSTEM OF THE EYE AFTER FEMTOSECOND INTRASTROMAL RING IMPLANTATION OF THE MYORING IN PATIENTS WITH HIGH MYOPIA IN COMBINATION WITH A THIN THICKNESS OF THE CORNEAAnalysis of changes in the aberrations of the optical system of the eye after femtosecond intrastromal Myoring implantation in patients with high myopia in combination with a thin thickness of the cornea. Femtosecond intrastromal Myoring implantation was performed in 43 eyes (of 24 patients) with an age from 24 to 45 years (mean of 34.5 ± 3 years) with high myopia in combination with a thin cornea thickness. Corneal aberrometry was studied on aberrometer (Visionix L80 WAVE+, Israel) before and 3 months after femtosecond intrastromal Myoring implantation. The value of the spherical component of the refraction was from –9.25 to –17.5 diopters (average 13.4 ± 1.4 diopters), cylindrical from –1.0 to –4.0 diopters (average 2.5 ± 1.2 d). The minimum value of pachymetry in the centre ranged from 430 to 498 μm (average of 464 μm ± 20 μm). The average keratometry value — 44.50 diopters. The level of higher-order and lower-order aberrations were evaluated. Spherical aberration and Coma aberrations have analyzed from higher-order aberrations. There is analysis of changes in the aberrations of the optical system of the eye after femtosecond intrastromal ring implantation of the MyoRing in patients with high myopia in combination with a thin thickness of the cornea. Uncorrected distance visual acuity (UDVA) has increased in 8 times after MyoRing implantation, corrected distance visual acuity (CDVA) — in 1.5 times, spherical component decreased in 8.5 times, cylindrical — in 2 times immediately after surgery. UDVA improved from 0.13 ± 0.01 3 months after surgery, CDVA has not changed. Analysis of the results indicates a high refractive efficiency of this method, the reduction of lower-order aberrations and increasing higher-order aberrations. So, analysis of changes in the aberrations of the optical system of the eye after femtosecond intrastromal Myoring implantation in patients with thin cornea during 3 months observation showed a reduction of lower-order aberrations and an increase in higher-order aberrations.Key words: myopia, corneal intrastromal Myoring implant, femtosecond laser,aberrations higher and lower-order.
References:
1. Avetisov S.E. Modern approaches to the correction of refractive disorders // Vestnik oftal'mologii. –2006. — No 1. — P. 3-8.
2. Aliev A-G.D., Ismailov M.I. Clinical classification of aberrations of optic system of human eye // Oftal'molog. Stran Prichernomor'ya: Proceedings. — Krasnodar,2006. — P.365-371.
3. Balashevich L.I. Refractive surgery. — SPb.: Izd. Dom SPbMAPO, 2002. — P.285.
4. Balashevich L.I., Kachanov A.B. Clinical corneotopography and aberrometry // Edited by prof. L.I.Balashevich. — М., 2008. — P.167.
5. Doga A.V., Kishkin Yu.I., Maychuk N.V. Дога А.В., Кишкин Ю.И., Майчук Н.В. Correction of "ultra-high" myopia by FemtoLASIK // Modern technologies of cataract and refractive surgery — 2011: proceedings. — М, 2011. — P. 227-231.
6. Kostin O.A., Rebrikov S.V., Ovchinnikov A.I. et al. The change in the coma aberration in the correction of myopia by the method of standard LASIK // Modern technologies of cataract and refractive surgery — 2009: proceedings — М, 2009. — P. 310-312.
7. Kulikova I.L., Pashtaev N.P. The first results of ametropia correction using femtosecond keratome // Clinical ophthalmology. — 2008. — No 3. — P. 87-90.
8. Maslova N.A., Pashtaev N.P. The long-term clinical and functional results after intrastromal keratoplasty using the IntraLase FS femtosecond laser in patients with keratoconus // Ophthalmosurgery. — 2011. — No 1. — P. 10-14.
9. Maslova N.A., Suslikov S.V. Formation of the intrastromal corneal tunnels for implantation of corneal segments in patients with keratoconus using the IntraLase FS femtosecond laser // Bul. SO RAMN. — 2009. — No. 4. — P. 75-79.
10. Moroz Z.I., Takhchidi Kh.P., Kalinnikov Yu.Yu., Kovshun E.V., Borzenok S.A. Modern aspects of keratoplasty. New technologies in the treatment of corneal diseases. All-Russian scientific-practical conference: materials. — М., 2004. — P. 280-287.
11. Neroev V.V., Oganesyan O.G., Penkina A.V., Khandzhyan A.T. The results of the implantation of intrastromal corneal segments using femtosecond surgical laser FEMTO LDV in patients with keratoconus of II-III stage // Proceedings of III Russian national ophthalmic Forum. — М., 2010. — Tom 1. — P. 137-141.
12. Pashtaev N.P., Pozdeeva N.A., Sinitsin M.V., Shlenskaya O.V. Correction of high myopia in conjunction with a thin cornea by the method of femtolaser intrastromal implantation of MyoRing ring // Cataract and refractive surgery. — 2013. — No 4. — P. 26-29.
13. Daxer A. Corneal intrastromal implantation surgery for the treatment of moderate and high myopia // J. Cataract Refract. Surg. — 2008. — Vol. 34, №2. — P.194 — 198.
14. Daxer A., Alio L., Pinero P. Clinical outcomes after complete ring implantation in corneal ectasia sing the femtosecond technology // Ophthlmology. — 2011. — Vol. 118, №7. — P. 1282-1290.
15. Miller J.M., Anwaruddin R., Straub J. et al. Higher order aberration in normal, dilated, intraocular lens, and laser in situ keratomileusis corneas // J. Refact. Surg. . — 2002. — Vol. 18, №5. — P.579 — 583.
About this article
Authors: Unishkova L.I., Pashtaev N.P., Pozdeeva N.A.
Year: 2015
|
|
 Editor-in-chief |
Sergey Aleksandrovich MIROSHNIKOV |
|
|