Adzhieva M.D., Shalagin R.V., Lelyukhin A.S., Kanygina O.N. EFFECT OF CONDITIONS OF GENERATION OF X-RADIATION AT MEASUREMENTS OF POROSITY OF CERAMIC MATERIALS BY A RADIATION METHODThe problem of creating porosity of radiation measuring instrument is discussed. Method of making the calibration samples is described. Shows the influence of the conditions of X-ray emission on the measurement results. Found that the reduction scattering coefficient is linearly dependent on the porosity of the ceramic samples.Key words: macro porosity, the reduction scattering coefficient, x-ray radiation.
References:
1. Adzhieva M.D., Kuvshinov N.A., Lelyukhin A.S., Kanygina O.N. Assessment of porosity materials reduced scattering coefficient value // Vestnik OSU. — 2012. — №9 (145). — S. 118-122.
2. Kanygina O.N., Chetverikova A.G., Lazarev D.A., Sal'nikova E.V. High-temperature phase transitions in iron-bearing clays of Orenburg // Vestnik OSU. — 2010. — №6 (112). — S. 113-118.
3. Anisina I.N., Kanygina O.N., Chetverikova A.G. Synthesis of siliceous ceramics. — Deutschland: LAP LAMBERT Academic Publishing GmbH & Co. Co. KG, 2012. — 82. ISBN 978-3-84542805-5.
4. Karyagin M.A., Muslumov D.A., Lelyukhin A.S. "Module calculate the reduction scattering coefficient for the model of radiation kilovoltmeter." Certificate of state registration of the computer number 2012618284 from 12.09.2012. The Federal Service for Intellectual Property, Patents and Trademarks. Russia.