Vestnik On-line
Orenburg State University november 20, 2024   RU/EN
Headings of Vestnik
Pedagogics
Psychology
Other

Search
Vak
Антиплагиат
Orcid
Viniti
ЭБС Лань
Rsl
Лицензия Creative Commons

2013, № 4 (153)



Kachanov A.B., Balashevich L.I., Bauer S.M., Zimin B.A., Novak Ya.N. TONOMETRIC IOP INDICATORS AFTER LASIK SURGERY FOR MYOPIA Myopic LASIK provokes to decreasing of central corneal thickness and correlates with the post-LASIK reducing of pneumotonometry and Maklakoff tonometry. The authors confirmed, that pneumotonometry data reducing more faster, than Maklakoff one, but there is statistical significant reducing of tonometric IOP in both cases. Key words: LASIK, pneumotonometry, Maklakov tonometry, central corneal thickness, IOP, myopia.

Download
References:

1. Balashevich L.I., Kachanov A.B., Nikulin S.A., Golovatenko S.P., Bauer S.M., Zimin B.A. Effect of corneal thickness on intraocular pressure indicators // Eye biomechanics — 2004. М.: Helmholtz Institute of Eye Diseases — 2004. — P. 89 — 91.

2. Balashevich L.I., Kachanov A.B., Nikulin S.A., Golovatenko S.P., Bauer S.M., Zimin B.A. Effect of corneal thickness on pneumotonometric intraocular pressure indicators // Ophthalmosurgery. — 2005. — №1. — P. 29 — 31.

3. Balashevich L.I., Kachanov A.B., Novak Ya.N., Bauer S.M., Zimin B.A. About the effect of corneal thickness on intraocular pressure indicators // Eye biomechanics — 2005, Proceedings of I confer. Moscow Helmholtz institute of eye Diseases, 2005. — P. 119 — 120.

4. Balashevich L.I., Litvin I.B., Kachanov A.B. Intraocular pressure and corneal thickness before and after excimer laser interference // EAKO — VI. — 2012. — Materials of VI Euro-Asian confer. in ophthalmology, 2012. — P. 68 — 69.

5. Tarutta Ye.P., Yerichev V.P., Larina T.Yu. Level control of IOP after keratorefractive operations // Eye biomechanics — 2004. М.: Helmholtz institute of eye Diseases. — 2004. — P.120 — 122.

6. Faucher A., Gregoire J., Blondeau P. Accuracy of Goldmann tonometry after refractive surgery // J. Cataract. Refract. Surg. — 1997. — Vol. 23. — P. 832 — 838.

7. Langham M.E., O'Brein T.P. Errors of Goldmann applanation tonometry following corneal Lasik surgery // Ophthalmology on the turn of centuries. Anniversary scientific conference, dedicated to 80 birthday anniversary of prof. V.V. Volkov, 2001, Proceedings. — 2001. — P. 124.


About this article

Authors: Kachanov A.B., Balashevich L.I., Bauer S.M., Zimin B.A., Novak Ya.N.

Year: 2013


Editor-in-chief
Sergey Aleksandrovich
MIROSHNIKOV

Crossref
Cyberleninka
Doi
Europeanlibrary
Googleacademy
scienceindex
worldcat
© Электронное периодическое издание: ВЕСТНИК ОГУ on-line (VESTNIK OSU on-line), ISSN on-line 1814-6465
Зарегистрировано в Федеральной службе по надзору в сфере связи, информационных технологий и массовых коммуникаций
Свидетельство о регистрации СМИ: Эл № ФС77-37678 от 29 сентября 2009 г.
Учредитель: Оренбургский государственный университет (ОГУ)
Главный редактор: С.А. Мирошников
Адрес редакции: 460018, г. Оренбург, проспект Победы, д. 13, к. 2335
Тел./факс: (3532)37-27-78 E-mail: vestnik@mail.osu.ru
1999–2024 © CIT OSU