Vestnik On-line
Orenburg State University december 23, 2024   RU/EN
Headings of Vestnik
Pedagogics
Psychology
Other

Search
Vak
Антиплагиат
Orcid
Viniti
ЭБС Лань
Rsl
Лицензия Creative Commons

2015, № 12 (187)



Aznabaev R.A., Shavaleeva K.R. PREVENTION OF DEHYDRATION CORNEAL FLAP DURING THE PROCEDURE LASIKLASIK procedure in patients with high myopia is related with a long period and increasing depth of ablation. These featuresmay cause postoperative complications such as epithelial ingrowth under the flap, aseptic inflammation,flap dystrophy syndrome, thereby reducing patient satisfaction and lengthening the period of rehabilitation after surgery, as well as the development of dry eye disease. 1 month after surgery average score of lacrimal functional complex assessment in the study group was 3.1±0.7. In 8 patients (33 %) state of lacrimal functional complex was in the normal range (0 points), 16 (64 %) — borderline (1 to 10 points). Average score in comparison group was higher than in the study (5.2 ± 1.3, p < 0.05). Lacrimal functional complex was within normal limits in 3 patients (15 %), 17 (85 %) — in a boundary condition. At 3-month follow-average score was 1.9 ± 1.1) and 3.6 ± 0.8) (p < 0.05), lacrimal functional complex within the normal range in 14 and 6 patients, respectively. Application of the proposed method of protection of corneal flap from dehydration during LASIK in a limited surgical field, prevents the flap shrinkage, thus contributing the full adaptation of the flap edges to avoid postoperative complications and to achieve maximum optical effects, as well as reduce the risk of dry eye in patients with high myopia.Key words: LASIK, dry eyesyndrome, protection flap.

Download
References:

1. Brzhesky V. V., E.E's Som. Diagnostics and treatment of patients with a syndrome of "a dry eye": The short management for doctors — SPb., 2005. — 20 pages.

2. Kashnikova O. A. Clinical features of "a dry eye" in photorefraction surgery//New technologies in treatment of diseases of a cornea. — Page 685-688

3. Kashnikova O. A., Maychuk D.Yu., Kurenkov V. V., Polunin G. S. Simptomatichesky "a dry eye" in photorefraction surgery//Fedorovsky readings — 2002. — Page 165 — 169

4. Kugoyeva E.A., Sokolovsky G. A. To a technique of research of bazalny secretion of a tear//the Messenger of ophthalmology. — 1996. — T.112. — No. 1. — Page 15-17

5. Azuma M, Yabuta C, Fraunfelder FW, Shearer TR. Dry eye in LASIK patients. BMC Res Notes. 2014 Jul 3;7:420.

6. Battat L., Marci A., Dursun M.et al. Effect of Laser in situ keratomileusis on tear production and the ocular surface // Ophthalmology.2001. — Vol. — P. 1230 — 1235

7. Burrato L., Brint S. LASIK Surgical Techniques and compilations // Hard.Cover. — 2000. — 624 p

8. Lane S., Koval R., Combined treatment of dry eye after surgery // OSN.Supplement to March 15, — 2000. — p.49

9. Lee JB, Ryu CH, Kim J, Kim EK, Kim HB. Comparison of tear secretion and tear film instability after photorefractive keratectomy and laser in situkeratomileusis. J Cataract Refract Surg. 2000;26(9):1326–1331.

10. McDonald M. Dry eye complication after LASIK // Euro Times. — 2001. — Vol.6. — No.4. — P.24-27

11. De Paiva C, Chen Z, Koch D, et al. The incidence and risk factors for developing dry eye after myopic LASIK. Am J Ophthalmol.2006;141(3):438–445.

12. Solomon R, Donnenfeld ED, Perry HD. The effects of LASIK on the ocular surface. Ocul Surf. 2004;2(1):34–44.

13. Sutton GL, Kim P. Laser in situ keratomileusis in 2010 — a review. Clin Experiment Ophthalmol. 2010;38(2):192–210.

14. Turu L, Alexandrescu C, Stana D, Tudosescu R. Dry eye disease after LASIK. J Med Life. 2012 Feb 22;5(1):82-4.

15. Toda I, Asano-Kato N, Komai-Hori Y, Tsubota K. Dry eye after laser in situ keratomileusis. Am J Ophthalmol. 2001;132(1):1–7.


About this article

Authors: Aznabaev R.A., Shavaleeva K.R.

Year: 2015


Editor-in-chief
Sergey Aleksandrovich
MIROSHNIKOV

Crossref
Cyberleninka
Doi
Europeanlibrary
Googleacademy
scienceindex
worldcat
© Электронное периодическое издание: ВЕСТНИК ОГУ on-line (VESTNIK OSU on-line), ISSN on-line 1814-6465
Зарегистрировано в Федеральной службе по надзору в сфере связи, информационных технологий и массовых коммуникаций
Свидетельство о регистрации СМИ: Эл № ФС77-37678 от 29 сентября 2009 г.
Учредитель: Оренбургский государственный университет (ОГУ)
Главный редактор: С.А. Мирошников
Адрес редакции: 460018, г. Оренбург, проспект Победы, д. 13, к. 2335
Тел./факс: (3532)37-27-78 E-mail: vestnik@mail.osu.ru
1999–2024 © CIT OSU