Vestnik On-line
Orenburg State University december 23, 2024   RU/EN
Headings of Vestnik
Pedagogics
Psychology
Other

Search
Vak
Антиплагиат
Orcid
Viniti
ЭБС Лань
Rsl
Лицензия Creative Commons

2013, № 4 (153)



Makovkin E.M., Kuznetsova O.S. THE RESULTS OF LASIK ON THIN AND ULTRA-THIN CORNEAThere were compared the results of 113 LASIK procedures (57 patients) performed on thin and ultra-thin cornea. It was revealed that application of mechanical longitudinal microkeratome "Moria" One-Use-Plus SBK ensures consistent and precise creation of a thin corneal flap which makes excimer laser surgery safe and effective even when dealing with thin and ultrathin corneas.Key words: thin cornea, corneal flap, LASIK, One-Use-Plus SBK.

Download
References:

1. Аvetisov S.E., Borodina N.V., Kobzova M.V. et al. Current approaches to evaluation of the anatomic and functional status of the cornea// Journal of ophthalmology. — 2010. — №4. — P. 59-63.

2. Kolotov M.G. To the question on corneal response to myopia correction by the method of LASIK// J. Ophthalmosurgery. — 2009. — №3.– P. 9-11.

3. Pateeva T.Z., Pashtaev N.P. IntraLASIK and LASIK for myopia correction (comparative analysis) // J. Ophthalmosurgery. — 2010. — №5. — P. 4-12.

4. Azar D.T., Chanem R.C., de la Cruz J et al. Thin-flap (sub-Bowman keratomileusis) versus thick — flap laser in situ keratomileusis for moderate to high myopia: case-control analysis // J. Cataract. Refract. Surg. — 2008. — №12. — P. 2073-2078.

5. Du S., Lian J., Zhang L. et al. Flap thickness variation with 3 types of microkeratome heads // J. Cataract. Refract. Surg. — 2011. — №1. — P.144-148.

6. Kymionis GD, Portaliou DM, Tsiklis NS et al. Thin LASIK flap creation using the SCHWIND Carriazo-Pendular microkeratome // J. Refract. Surg. — 2009. — V.25. -№1. — P.33-36.

7. Yau C.W., Cheng H.C. Microkeratome blades and corneal flap thickness in LASIK // Ophthalmic. Surg. Lasers. Imaging. — 2008. — V.39. — №6. — Р. 471-475.

8. Mian SILi AYDutta SMusch DCShtein R.M. Dry eyes and corneal sensation after laser in situ keratomileusis with femtosecond laser flap creation: effect of hinge position, hinge angle, and flap thickness. // J. Cataract. Refract. Surg. — 2009. — V. 35 (12). — P. 2092- 2098.


About this article

Authors: Makovkin E.M., Kuznetsova O.S.

Year: 2013


Editor-in-chief
Sergey Aleksandrovich
MIROSHNIKOV

Crossref
Cyberleninka
Doi
Europeanlibrary
Googleacademy
scienceindex
worldcat
© Электронное периодическое издание: ВЕСТНИК ОГУ on-line (VESTNIK OSU on-line), ISSN on-line 1814-6465
Зарегистрировано в Федеральной службе по надзору в сфере связи, информационных технологий и массовых коммуникаций
Свидетельство о регистрации СМИ: Эл № ФС77-37678 от 29 сентября 2009 г.
Учредитель: Оренбургский государственный университет (ОГУ)
Главный редактор: С.А. Мирошников
Адрес редакции: 460018, г. Оренбург, проспект Победы, д. 13, к. 2335
Тел./факс: (3532)37-27-78 E-mail: vestnik@mail.osu.ru
1999–2024 © CIT OSU