Vestnik On-line
Orenburg State University april 28, 2024   RU/EN
Headings of Vestnik
Pedagogics
Psychology
Other

Search
Vak
Антиплагиат
Orcid
Viniti
ЭБС Лань
Rsl
Лицензия Creative Commons

2013, № 4 (153)



Kishkin Yu.I., Takhchidi N.Kh. EFFECTIVENESS OF THE Q-VALUE GUIDED FEMTOLASIK FEMTO-VISUMQ-value guided FemtoLASIK Femto-Visum is shown to be effective. The aberrations changed slightly after Q-value guided FemtoLASIK from conventional FemtoLASIK.Key words: myopia, visual quality, aberrations, Q-value, FemtoLasik.

Download
References:

1. Balashevich L.I. Optical aberration: diagnostics and correction // Оculist.-2001-№6 (22).-P.12-15.

2. Egorova G.B, Borodina N.V., Bybnova I.A. Aberrations of human eye, ways of measuring and correcting//Russian Medical journal.-2003.-Т.4.-№4.-P.4-9.

3. Semchishen V., Mrokhen M., Sailer Т. Optical aberrations of human eye and their correction //Refractive surgery and ophthalmology.-2003.-Т.3-№1.-P.5-13.

4. Buzzonetti L, Petrocelli G, Valente P, Tamburrelli C, Mosca L, Laborante A, Balestrazzi E. Comparison of corneal aberration changes after laser in situ keratomileusis performed with mechanical microkeratome and IntraLase femtosecond laser: 1-year follow-up.//Cornea.- 2008 — Vol.27. — P. 174-9.

5. Krueger RR, Dupps WJ Jr.Biomechanical effects of femtosecond and microkeratome-based flap creation: prospective contralateral examination of two patients. // J Refract Surg. -2007 — Vol.23. — P. 800-7.

6. Llorente L., Barbero S., Merayo J., Marcos S., Total and corneal optical aberrations induced by laser in situ keratomileusis // J. RefractSurg.-2004.-Vol.20.-P.203-216.

7. Medeiros FW, Stapleton WM, Hammel J, Krueger RR, Netto MV, Wilson SE. Wavefront analysis comparison of LASIK outcomes with the femtosecond laser and mechanical microkeratomes. //J Refract Surg. — 2007 — Vol.23.-P. 880-7.

8. Tran DB, Sarayba MA, Bor Z, Garufis C, Duh YJ, Soltes CR, Juhasz T, Kurtz RM. Randomized prospective clinical study comparing induced aberrations with IntraLase and Hansatome flap creation in fellow eyes: potential impact on wavefront-guided laser in situ keratomileusis. // J Cataract Refract Surg. 2005 Jan. –Vol.31. — P. 97-105.

9. Zernike F. Beugungstheorie des Schneindenverfahrens und seiner verbesserten Form der Phasenkontrastmethode // Physical.-1934.-No.2.-P.689-704.

10. Zhang ZH, Jin HY, Suo Y, Patel SV, Montes-Mico R, Manche EE, Xu X. Femtosecond laser versus mechanical microkeratome laser in situ keratomileusis for myopia// J Cataract Refract Surg. -2011 Dec. –Vol.37.– P. 2151-9.


About this article

Authors: Tahchidi N.H., Kishkin Yu.I.

Year: 2013


Editor-in-chief
Sergey Aleksandrovich
MIROSHNIKOV

Crossref
Cyberleninka
Doi
Europeanlibrary
Googleacademy
scienceindex
worldcat
© Электронное периодическое издание: ВЕСТНИК ОГУ on-line (VESTNIK OSU on-line), ISSN on-line 1814-6465
Зарегистрировано в Федеральной службе по надзору в сфере связи, информационных технологий и массовых коммуникаций
Свидетельство о регистрации СМИ: Эл № ФС77-37678 от 29 сентября 2009 г.
Учредитель: Оренбургский государственный университет (ОГУ)
Главный редактор: С.А. Мирошников
Адрес редакции: 460018, г. Оренбург, проспект Победы, д. 13, к. 2335
Тел./факс: (3532)37-27-78 E-mail: vestnik@mail.osu.ru
1999–2024 © CIT OSU