2013, № 4 (153)


Kachanov A.B., Balashevich L.I., Bauer S.M., Zimin B.A., Novak Ya.N.
TONOMETRIC IOP INDICATORS AFTER LASIK SURGERY FOR MYOPIA
Myopic LASIK provokes to decreasing of central corneal thickness and correlates with the post-LASIK reducing of pneumotonometry and Maklakoff tonometry. The authors confirmed, that pneumotonometry data reducing more faster, than Maklakoff one, but there is statistical significant reducing of tonometric IOP in both cases.
Key words: LASIK, pneumotonometry, Maklakov tonometry, central corneal thickness, IOP, myopia.