Pilyagina A.A. THE OPPORTUNITIES OF THE DIFFERENT BIOMETRY METHODS IN OCULAR AXIAL LENGTH ASSESSMENTThe question about intraocular correction improvement remains open. The latest diagnostic techniques introduction of measuring biometric eye parameters aims at improving the calculation accuracy of the intraocular lens optical power and at refractive error reduction in postoperative period.The accuracy of the intraocular lens power calculation suffers because the accurate biometry methods are not widely used and are not applied in the absolute majority of patients. Errors when measuring the anterior posterioreyeball axis (APA) determine from 40 to 54 % of mistakes in the postoperative refractive result. The aforesaidtestifies to the urgency of the chosen topic, and identifies the aim of our work: the comparative investigation of the opportunities of different biometry methods in ocular axial length assessment. There were analyzed the results of the anterior posterior ocular axis measurements in 27 patients (46 eyes) using the ultrasound applanation and immersion biometry and optical biometry. The results of our investigation showed that the difference in APA measurements using these methods of biometry is minimum and statistically insignificant.However, when comparing the measurements obtained by optical and applanation ultrasonic biometry, there has been a trend towards reduction of APA indices, because of the possible corneal compression in applanation of the ultrasonic sensor. The results of APA indices, measured by the immersion and optical biometry, are comparable with each other. Thus, immersion method of the ultrasound biometry lacks forapplanationmethod disadvantages, namely corneal compression, is usedin any degree of mature cataract and corneal opacification, according to the biometric measurements accuracy it is not inferior to the optical method and can be an alternative to optical biometry.Key words: ultrasound immersion biometry, ultrasound applanation biometry, optical biometry, anterior posterior ocular axis.

Download
References:

1. Gale R.P., Saldana M., Johnston R.L., Zuberbuhler B., McKibbin M. Benchmark standards for refractive outcomes after NHS cataract surgery. // Eye. 2009. Vol. 23. P. 149-152.

2. Eleftheriadis H. IOLMaster biometry: refractive results of 100 consecutive cases. // Br. J. Ophthalmol. 2003. Vol. 87. P. 960-963.

3. Olsen T. Sources of error in intraocular lens power calculation. // J. Cataract. Refract. Surg. 1992. Vol. 18. P. 125-129.

4. Olsen T. The accuracy of ultrasonic determination of axial length in pseudophakic eyes. // Acta Ophthalmol (Copenh). 1990. Vol. 67. P. 141-144.

5. Hughes G.F. // Am. J. Ophthalmol. 1956. Vol. 41. P. 488-498.

6. Mundt G.H., Hughes G.F. // Am. J. Ophthalmol. 1956. Vol. 41. P. 488-498.

7. Fridman F.E., Gundorova R.A., Kodzov M.B. Ultrasound in ophthalmology. M.: Medicine, 1989. P. 50.

8. Balashevich L.I., Danilenko E.V. The peculiarities of the intraocular lens power calculation in phacoemulsification. SPb., SPbMAPO, 2011. P. 9-17.

9. Butcher J.M. The reproducibility of biometry and keratometry measurements. // Eye. 1991. Vol.5. P. 708-711.

10. Neroev V.V., Kiselyova T.N., Oganisyan O.G. The comparative assessment of the ocular biometry methods in the accuracy of the optic power calculation // Proceedings of the conference "East-West", 2013. P. 145.

11. Fercher A.F., Mengedoht K., Werner W. Eye length measurement by interferometry with partially coherent light. // Optics Letters. 1988. Vol. 13. P. 186-188.

12. Avetisov S.E., Voroshilova N.A., Ivanov M.N. Optical coherence biometry // Bulletin of ophthalmology. 2007. №4. P. 46-47.

13. Haigis W., Lege B., Miller N., Schneider B. // Graefes Arch. Clin. Exp. Ophthalmol. 2000. Vol. 238. P. 765-773.

14. Kiss B., Findl O., Menapace R. et. al. // J. Cataract. Refract. Surg. 2002. Vol. 28. P. 230-234.

15. Packer M., Fine I.H., Hoffman R.S. et. al. // J. Cataract. Refract. Surg. 2002. Vol. 28. P. 239-242.


About this article

Author: Pilyagina A.A.

Year: 2015


Editor-in-chief
Sergey Aleksandrovich
MIROSHNIKOV

Crossref
Cyberleninka
Doi
Europeanlibrary
Googleacademy
scienceindex
worldcat
© Электронное периодическое издание: ВЕСТНИК ОГУ on-line (VESTNIK OSU on-line), ISSN on-line 1814-6465
Зарегистрировано в Федеральной службе по надзору в сфере связи, информационных технологий и массовых коммуникаций
Свидетельство о регистрации СМИ: Эл № ФС77-37678 от 29 сентября 2009 г.
Учредитель: Оренбургский государственный университет (ОГУ)
Главный редактор: С.А. Мирошников
Адрес редакции: 460018, г. Оренбург, проспект Победы, д. 13, к. 2335
Тел./факс: (3532)37-27-78 E-mail: vestnik@mail.osu.ru
1999–2024 © CIT OSU