Galimova A.B., Pervushin Yu.S. ESTIMATION OF MATERIALS POSSIBILITIES TO FORMATION OF IMPRESSION ROBUST BANK ON THE BASE OF MECHANICAL PROPERTIES A preclinical evaluation of an ability of the silicone sponge and biomaterial for scleral buckling to create a reliable buckling effect was done. The mechanical properties of the materials were tested by an axial compression. An elasticity modulus and proportional elastic limit were measured. It was established that the flexibility and pliability of the silicone sponge can result in an unsufficient buckling effect. In contrast, higher elasticity and stiffness of the biomaterial for scleral buckling provide a reliable and controlled intendation.Key words: scleral buckling, biomaterial, elasticity, pliability.

Download
References:

1. Antonova M.D. Application of textile grafts from polyether material for surgical treatment of retinal detachment. Author's abstract … cand. med. sciences. – Moscow, 2007. – 28p.

2. Volkov V.V., Brzheskiy V.V., Ushakov N.A. Ophthalmosurgery with polymers application. – SPb: Gippokrat, 2003. – P.5-37, 261-309

3. Galimova A.B. Sclera filling by biomaterial Alloplant at rhegmatogenous retinal detachment // Eroshevskiye chteniya: theses. – Samara, 2012. – P.293-296

4. Iosilevich G.B., Lebedev P.A., Strelyayev V.S. Applied mechanics: for students of universities. – М., 1985. – P.146-168, 233-238, 250-270

5. Kreyssig I. Minimal surgery of retinal detachment: Practical guidance / translated from english. – In 2 vol. – М., 2005 – Vol.1 – 289 p.

6. Lectures at applied mechanics: electronic instructional course for students of universities/ author: Karimov I.I. – Ufa, 2010. URL: http://www.prikladmeh.ru/lect.html

7. Elastomer and India rubbers. URL: http://kalinaplast.ru/maim/informaciya/stati/751/731.html (the data of resort: 20.09.2012)

8. Lansman S. Evaluation of bioabsorbable poly-L/D-lactide implant for scleral buckling. An experimental study // Acta Univ. Oul. D Medica 1039, 2009.


About this article

Authors: Galimova A.B., Pervushin Yu.S.

Year: 2012


Editor-in-chief
Sergey Aleksandrovich
MIROSHNIKOV

Crossref
Cyberleninka
Doi
Europeanlibrary
Googleacademy
scienceindex
worldcat
© Электронное периодическое издание: ВЕСТНИК ОГУ on-line (VESTNIK OSU on-line), ISSN on-line 1814-6465
Зарегистрировано в Федеральной службе по надзору в сфере связи, информационных технологий и массовых коммуникаций
Свидетельство о регистрации СМИ: Эл № ФС77-37678 от 29 сентября 2009 г.
Учредитель: Оренбургский государственный университет (ОГУ)
Главный редактор: С.А. Мирошников
Адрес редакции: 460018, г. Оренбург, проспект Победы, д. 13, к. 2335
Тел./факс: (3532)37-27-78 E-mail: vestnik@mail.osu.ru
1999–2024 © CIT OSU