Tsurova L.M., Milyudin E.S. , Zelter P.M., Kanivec N.V., Popov N.V. NEW IN CHOOSING OF OPTIMAL SIZE ORBITAL BONE IMPLANT [№ 12 ' 2015] In the prevention and treatment of anophthalmic syndrome is important to choose the optimal size implant for each individual patient. In our study we used CT scan of the orbits, the BMD of the eyeballs and facial radiography of the skull to calculate the optimal size of orbital bone liner, taking into consider anatomical parameters of the orbit. There are 60 patients without eye pathology, separated on three group depend on method of diagnostic research. Patients aged from 30 to 75. Analysis results of diagnostic tests have allowed us to develop new optimal size of orbital bone implant. Bone orbital implant is bone block with cylindrical form and porous structure, which had three type sizes. Our studies show, that orbital bone implant, which optimal size have developed in diagnostic researches, help us to create good functional and cosmetic result after enucleation. We offer complex researches of orbit (CT scan of the orbits, eyes ultrasound biometry, facial skull radiography), that is optimal set of researches for calculation of type sizes bone orbital implant. |
|
Editor-in-chief |
Sergey Aleksandrovich MIROSHNIKOV |
|
|