Vestnik On-line
Orenburg State University december 22, 2024   RU/EN
Headings of Vestnik
Pedagogics
Psychology
Other

Search
Vak
Антиплагиат
Orcid
Viniti
ЭБС Лань
Rsl
Лицензия Creative Commons

Sorokoletov G.V., Zuev V.K., Tumanjan J.R., Veshhikova V.N., Frankovska-Gerlyak M.Z.
THE RESULTS OF CORRECTION OF HIGH MYOPIA DOMESTIC PHAKIC INTRAOCULAR LENS [№ 12 ' 2015]
Currently it is widely used correction of high myopia (MIF) negative posterior chamber phakic lenses, but the question remains of conformity of the linear size of the PIOL to the diameter of the ciliary sulcus. High myopia correction by posterior chamber IOL implantation is very popular today but disproportion between the PIOL size and the ciliary sulcus diameter could be a reason for some complication at long-term follow-up. Therefore a new model of PIOL with adaptation ability to individual ciliary sulcus diameter was propounded. The PIOL is manufactured from hydrophilic acrylic (Contamac CI26) with water contains 26 % and refractive index 1.46. In result the new PIOL shows efficacy, safety and high adaptation ability.

Sorokoletov G.V., Zuev V.K., Tumanyan E.R., Veshchikova V.N.
THE SURGERY ACCESS CHOICE DURING CATARACT PHACOEMULSIFICATION [№ 4 ' 2013]
The most common incision for cataract surgery by phacoemulsification is corneal. But limbal incision has advantages associated with limbal regeneration function and disadvantages associated with conjunctiva chemosis in time of surgery. The introduced technology of limbal incision permits to avoid conjunctiva chemosis and get excellent results at the follow-up.

Ivanova Е.S., Tumanyan N.R., Lyubimova T.S., Subkhangulova E.A.
SELECTIVE LASER ACTIVATION OF TRABECULA IN TREATMENT OF PATIENTS WITH PRIMARY OPEN-ANGLE GLAUCOMA [№ 12 ' 2012]
To compare the effectiveness and safety of selective laser activation of trabecula (SLAT) with selective laser trabeculoplasty (SLT) in lowering intraocular pressure (IOP) in patients with primary open-angle glaucoma (POAG). SLAT results in a maximal trabecular meshwork cleaning and better IOP reduction compared with SLT


Editor-in-chief
Sergey Aleksandrovich
MIROSHNIKOV

Crossref
Cyberleninka
Doi
Europeanlibrary
Googleacademy
scienceindex
worldcat
© Электронное периодическое издание: ВЕСТНИК ОГУ on-line (VESTNIK OSU on-line), ISSN on-line 1814-6465
Зарегистрировано в Федеральной службе по надзору в сфере связи, информационных технологий и массовых коммуникаций
Свидетельство о регистрации СМИ: Эл № ФС77-37678 от 29 сентября 2009 г.
Учредитель: Оренбургский государственный университет (ОГУ)
Главный редактор: С.А. Мирошников
Адрес редакции: 460018, г. Оренбург, проспект Победы, д. 13, к. 2335
Тел./факс: (3532)37-27-78 E-mail: vestnik@mail.osu.ru
1999–2024 © CIT OSU