Vestnik On-line
Orenburg State University april 19, 2024   RU/EN
Headings of Vestnik
Pedagogics
Psychology
Other

Search
Vak
Антиплагиат
Orcid
Viniti
ЭБС Лань
Rsl
Лицензия Creative Commons

2015, № 12 (187)



Shukhayev S.V., Naumenko V.V., Boiko E.V. PHACOEMULSIFICATION WITH FEMTO-LASER SUPPORT IN EYES WITH ENDOTHELIAL DYSTROPHY OF FUCHSFemtosecond laser assisted cataract surgery (FLACS) is the most important innovation in cataract surgery in recent years. The purpose of the study was to assess the endothelial cell loss after FLACS procedure in the eyes with Fuchs' endothelial dystrophy. 50 patients (50 eyes) with Fuchs' endothelial dystrophy were included into this prospective clinical study. All patients had central cornea guttata with warts and low endothelial cell density at the center of the cornea. 23 patients underwent FLACS procedure and other 27 patients underwent conventional manual surgery. Endothelial cell densities were measured before and 1 day, 1 month after the surgery at 7 standardized points of the cornea. Prior to the surgery, both groups showed no difference in cataract grade, nuclear density and endothelial cell density (p > 0.05). Postoperatively endothelial cell loss was significantly greater in the manual group (p < 0.05). For the preservation of the endothelial integrity, FLACS proves to be safer procedure.Key words: Key world: femtosecond laser assisted cataract surgery, phacoemulsification, endothelial cell loss, Fuchs' endothelial dystrophy.

Download
References:

1. Kránitz K., Miháltz K., Sándor G.L., Takacs A., Knorz M.C., Nagy Z.Z. Intraocular lens tilt and decentration measured by Scheimpflug camera following manual or femtosecond laser-created continuous circular capsulotomy. J RefractSurg. 2012 Apr;28(4):259-63.

2. Filkorn T., Kovács I., Takács A., Horváth E., Knorz M.C., Nagy Z.Z. Comparison of IOL power calculation and refractive outcome after laser refractive cataract surgery with a femtosecond laser versus conventional phacoemulsification. J Refract Surg. 2012 Aug;28(8):540-4.

3. Filkorn T., Kovacs I., Kranitz K., Takacs A.I., Horvath E., Knorz M.C., Nagy Z.Z. Intraocular lens calculation results and refractive outcomes after femtosecond laser-assisted and conventional cataract surgery. In Femtosecond laser-assisted cataract surgery. Edit Nagy Z.Z. SLACK Inc. 2014. p.33-35.

4. Daya S.M., Nanavaty M.A., Espinosa-Lagana M.M. Translenticular hydrodissection, lens fragmentation, and influence on ultrasound power in femtosecond laser-assisted cataract surgery and refractive lens exchange. J Cataract Refract Surg. 2014 Jan;40(1):37-43.

5. Abell R.G., Darian-Smith E., Kan J.B., Allen P.L., Ewe S.Y., Vote B.J. Femtosecond laser-assisted cataract surgery versus standard phacoemulsification cataract surgery: Outcomes and safety in more than 4000 cases at a single center. J Cataract Refract Surg. 2015 Jan;41(1):47-52.

6. Krarup T., Holm L.M., la Cour M., Kjaerbo H. Endothelial cell loss and refractive predictability in femtosecond laser-assisted cataract surgery compared with conventional cataract surgery. ActaOphthalmol. 2014 Nov;92(7):617-22.

7. Conrad-Hengerer I., Hengerer F.H., Schultz T., Dick H.B. Effect of femtosecond laser fragmentation on effective phacoemulsification time in cataract surgery. J Refract Surg. 2012 Dec;28(12):879-83.

8. Kacerovská J., Kacerovský M., Kadlec R. Development of number of endothelial cells after cataract surgery performed by femtolaser in comparison to conventional phacoemulsification. CeskSlovOftalmol. 2013 Oct;69(5):215-8.


About this article

Authors: Boyko E.V., Shuhaev S.V., Naumenko V.V.

Year: 2015


Editor-in-chief
Sergey Aleksandrovich
MIROSHNIKOV

Crossref
Cyberleninka
Doi
Europeanlibrary
Googleacademy
scienceindex
worldcat
© Электронное периодическое издание: ВЕСТНИК ОГУ on-line (VESTNIK OSU on-line), ISSN on-line 1814-6465
Зарегистрировано в Федеральной службе по надзору в сфере связи, информационных технологий и массовых коммуникаций
Свидетельство о регистрации СМИ: Эл № ФС77-37678 от 29 сентября 2009 г.
Учредитель: Оренбургский государственный университет (ОГУ)
Главный редактор: С.А. Мирошников
Адрес редакции: 460018, г. Оренбург, проспект Победы, д. 13, к. 2335
Тел./факс: (3532)37-27-78 E-mail: vestnik@mail.osu.ru
1999–2024 © CIT OSU