Vestnik On-line
Orenburg State University december 23, 2024   RU/EN
Headings of Vestnik
Pedagogics
Psychology
Other

Search
Vak
Антиплагиат
Orcid
Viniti
ЭБС Лань
Rsl
Лицензия Creative Commons

2015, № 12 (187)



Fabrikantov O.L., Khaleeva D.V., Shutova S.V. THE COMPARATIVE ANALYSIS OF THE ANTERIOR-POSTERIOR OCULAR SEGMENT MEASUREMENT IN CHILDREN AND TEENAGERS WITH REFRACTION ANOMALYAccording to the data of World public health organization in 2014, 12 million children had visual impairment caused by the refractive anomalies — the conditions that could be easily diagnosed and corrected. On a global scale one of the main reasons of visual impairment in adults (43 %) is non-corrected refractive anomalies (myopia, hypermetropia, astigmatism), conditions reducing the life quality, and often leading to disability. The determination of the ocular axial length accuracy in children and teenagers with refraction anomaly is obligatory in diagnosis, and in myopia it is the only reliably objective method to determine its progression. At present, it is possible to perform the ultrasound (US) and optical biometry. Ultrasound (US) biometry is a contact method of investigation and "golden" standard in ophthalmology. Optical biometry (OBM) is a non-contact method and which is an advantage. The purpose of our study is to determine the accuracy of the ocular axial length values using the ultrasound and optical biometry methods in children and teenagers. The group of patients (54 people, 108 eyes) were examined using both methods. Also after the investigation, they were asked about the feeling of discomfort and pain. In the examination outcomes we took into account the characteristics of the absolute inter individual and intra individual variations of the examined signs, as well as the reproduction assessment of the echobiometry and optical biometry results. The ocular axial length measurement by the optical biometry provides with the more accurate values in comparison with the results obtained by the ultrasound echobiometry and it is well tolerated by patients.Key words: biometry, ultrasound biometry, optical biometry, anterior-posterior ocular segment.

Download
References:

1. Kvaratskheliya N.G. The comparative examination of the anatomic and functional peculiarities of the eyes with hypermetropy and myopia in children: author's abstract of dissertation MD. M., 2010. 26 p.

2. Avetisov S.E. Myopia. M.: Medicine, 2002. 288 p.

3. Kayetkina E.V. The outcomes of the ultrasound biometry of the eyeball in children with different myopic degree // Ophthalmological journal. 2004. №5. P. 25-29.

4. Mokhnacheva S.A., Rykun V.S., Grischenko N.V., Klyuchko N.A. Modern conceptions about myopia progression problem // Bulletin of Council of the young scientists and precialists in Chelyabinsk region. №1 (5). 2014. P. 60-64.

5. Pospelov V.I. Etiology, pathogenesis and principles of the pathogenic therapy in children with progressive myopia // Scientific practical conference of the ophthalmologists "Modern technologies of drug therapy in ophthalmology", proceedings of the meeting "Myopia". Krasnoyarsk, 2007. P. 3-23.

6. Jody A. Summers Rada, Setareh Shelton, Thomas T. Norton. The sclera and myopia//Experimental Eye Research Volume 82, Issue 2, February 2006, Pages 185-200.

7. Avetisov K.S., Markosyan A.G., Ambartsumyan A.R., Bubnova I.A. Biometry of the anterior segment ocular structure: comparative investigations // Bulletin of ophthalmology. 2010. № 6. С. 21-25.

8. Fridman F.E., Gundorova R.A., Kodzov M.B. Ultrasound in ophthalmology. M.: Medicine, 1989. 256 p.

9. Pavlin C. J., Foster F. S. Ultrasound biomicroscopy of the eye. Berlin: Springer-Verlag, 1995. 209 p.

10. Levchenko O.G., Drukman A.B. Ultrasound ocular biometry in children with different refraction // Bulletin of ophthalmology. 1976. №5. P. 47-50.

11. Nikolov V.B. Ultrasound ocular biometry in myopia // Bulletin of ophthalmology. 1980. №5. P. 39-43.

12. Avetisov S.E., Voroshilova N.A., Ivanov M.N. Optical coherence biometry // Bulletin of ophthalmology. 2007. № 4. С. 46-48.

13. Li Y., ShekarR., Huang D. Corneal pachymetry mapping with high-speed optical coherence tomography // Ophthalmology. 2006. Vol. 113, N5. P. 779-783.

14. Nikolov V.B. Ultrasound ocular biometry in myopia and its pathogenesis. Abstract of dissertation PhD. M., 1979. 15 p.

15. Schmitt J.M., "Optical Coherence Tomography (OCT): A Review," IEEE J. Sel. Top. In Quant. Electr., 5, 1205-1215, (1999).


About this article

Authors: Haleeva D.V., Fabrikantov O.L., Shutova S.V.

Year: 2015


Editor-in-chief
Sergey Aleksandrovich
MIROSHNIKOV

Crossref
Cyberleninka
Doi
Europeanlibrary
Googleacademy
scienceindex
worldcat
© Электронное периодическое издание: ВЕСТНИК ОГУ on-line (VESTNIK OSU on-line), ISSN on-line 1814-6465
Зарегистрировано в Федеральной службе по надзору в сфере связи, информационных технологий и массовых коммуникаций
Свидетельство о регистрации СМИ: Эл № ФС77-37678 от 29 сентября 2009 г.
Учредитель: Оренбургский государственный университет (ОГУ)
Главный редактор: С.А. Мирошников
Адрес редакции: 460018, г. Оренбург, проспект Победы, д. 13, к. 2335
Тел./факс: (3532)37-27-78 E-mail: vestnik@mail.osu.ru
1999–2024 © CIT OSU