Вестник On-line
Оренбургский государственный университет 19 ноября 2024   RU/EN
Рубрики Вестника
Педагогика
Психология
Другие

Поиск
Vak
Антиплагиат
Orcid
Viniti
ЭБС Лань
Rsl
Лицензия Creative Commons

2013, № 5 (154)



УДК: 621.039.51Badawi M.S., El-Khatib A.M., Elzaher M.A., Thabet A.A., Sakr A.A. USING AN ANALYTICAL EFFICIENCY TRANSFER PRINCIPLE TO CALCULATE THE FULL ENERGY PEAK EFFICIENCY FOR GAMMA DETECTORSIn this work the Full-Energy Peak Efficiency of NaI(Tl) — scintillation detectors (5.08x5.08 cm2 and 7.62x7.62 cm2) values have been calculated for axial cylindrical sources of different dimensions larger than the detectors using an analytical approach of effective solid angle calculation. This approach is based on the ratio of the source-detector solid angle with taken the source self absorption effect in to account. The detector efficiency for various geometrical conditions is derived from the known efficiency for reference source-detector geometry. The present method shows a great possibilities to calibrate the detectors through the determination of the full-energy peak efficiency curve even in those case when no standard source is available and this consider as the final goal of this work. Ключевые слова: NaI (Tl) detector, Full-Energy Peak Efficiency, Efficiency Transfer.

Загрузить
Список использованной литературы:

1. Le'py M.C., Altzitzoglou, T., Arnold, D., etal., 2001. Intercomparison of efficiency transfer software for gamma-ray spectrometry. Appl. Radiat. Isot. 55(4), 493–503.

2. Vidmar T., Aubineau Laniece, I., Anagnostakis, M.J., et al., 2008. An intercomparison of Monte Carlo codes used in gamma-ray spectrometry. Appl. Radiat. Isot. 66 (6–7), 764–768.

3. Abbas M.I. Appl. Radiat. Isot. 54 (2001), 761.

4. Abbas M.I. and Selim Y.S. Nucl. Instrum. Methods Phys. Res. A, 480/2-3 (2002) 649.

5. Abbas M.I., Nafee S.S. and Selim Y. S. Radiation Physics and Chemistry. 75 (2006) 729.

6. Abbas M.I. Journal of Physics D: Applied Physics 39 (2006) 3952.

7. Pibida L., Nafee S.S., Unterweger M., Hammond M.M., Karam L. and Abbas M. I. Applied Radiation and Isotopes Journal, 65 (2007) 225.

8. Abbas M.I. Nucl. Instrum. Methods Phys. Res. B, 256 (2007) 554.

9. Abbas M.I. Nuclear Technology 168 (2009) 41.

10. Abbas M.I. Nucl. Instrum. Methods Phys. Res. A, 615 (2010) 48.

11. Nafee S.S., Badawi M.S., Abdel-Moneim A.M., Mahmoud S.A. "Calibration of the 4р г-ray spectrometer using a new numerical simulation approach" Applied Radiation and Isotopes 68 (2010) 1746–1753

12. Debertin K. and Schotzig, U. 1979. Coincidence summing corrections in Ge(Li)-spectrometry at low source-to-detector distances, Nucl. Instrum. Meth. A158, 471.


О статье

Авторы: Bаdаwi М.S., El-Кhаtib А.М., Elzаhеr М.А., Sakr А.А., Thаbеt А.А.

Год: 2013


Главный редактор
Сергей Александрович
МИРОШНИКОВ

Crossref
Cyberleninka
Doi
Europeanlibrary
Googleacademy
scienceindex
worldcat
© Электронное периодическое издание: ВЕСТНИК ОГУ on-line (VESTNIK OSU on-line), ISSN on-line 1814-6465
Зарегистрировано в Федеральной службе по надзору в сфере связи, информационных технологий и массовых коммуникаций
Свидетельство о регистрации СМИ: Эл № ФС77-37678 от 29 сентября 2009 г.
Учредитель: Оренбургский государственный университет (ОГУ)
Главный редактор: С.А. Мирошников
Адрес редакции: 460018, г. Оренбург, проспект Победы, д. 13, к. 2335
Тел./факс: (3532)37-27-78 E-mail: vestnik@mail.osu.ru
1999–2024 © ЦИТ ОГУ